SAR测试基础标准IEC 62209-1重大更新
为了适应市场的要求,国际IEC的标准也不断的更新中。IEC(International Electrotechnical Commission)于2016年7月发布新版本的SAR (比吸收率) 测试基础标准之一, IEC 62209-1,详情如下:IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
IEC 62209-1:2016方法针对手持和身体佩戴使用的无线通信设备对人体的电磁照射的测量程序的评估—第1部分:靠近耳边使用的手持式无线通信设备的SAR评估规程(频率范围300 MHz~6 GHz)。
u IEC 62209-1:2016总概
Ü IEC62209-1:2016 specifies protocols and test procedures for measurement of the peak spatial-average SAR induced inside a simplified model of the head with defined reproducibility. It applies to certain electromagnetic field (EMF) transmitting devices that are positioned next to the ear, where the radiating structures of the device are in close proximity to the human head, such as mobile phones, cordless phones ,certain headsets, etc. These protocols and test procedures provide a conservative estimate with limited uncertainty for the peak-spatial SAR that would occur in the head for a significant majority of people during normal use of these devices. The applicable frequency range is from 300 MHz to 6 GHz.
IEC62209-1:2016 规定了在具有确定的再现性的头部的简化模型内测量的峰值空间平均SAR的协议和测试程序。 其适用于定位在耳朵附近的某些电磁场(EMF)传输装置,其中装置的辐射结构靠近人类头部,例如移动电话,无绳电话,某些耳机等。这些协议和测试程序提供保守估计,对于在正常使用这些设备期间对于绝大多数人而言在头部中将发生的峰值空间SAR的有限的不确定性。 适用的频率范围为300 MHz至6 GHz。
Ü This second edition cancels and replaces the first edition published in 2005. This edition constitutes a technical revision.
第二版 取消并取代2005年发行的**版。该版本构成技术修订版。
u 新版标准的主要更新如下:
Ü Extension of the frequency range to 300 MHz to 6GHz.
频率范围扩展至300 MHz 到6 GHz (2005版本:300 MHz 到3 GHz)。
Ü Fast SAR methods.
为减少测试时长,引入**扫描Fast SAR测试方法。
Ü Test reduction techniques.
同样从减少测试时长的角度考虑,新增测试配置减少判定程序,主要从以下四个方面来考虑:
Ø Test reduction for different operating modes at the same test frequency band using the same wireless technology
基于样品在相同频段内、运用相同技术,而处于不同工作模式的测试减少程序。
Ø Test reduction based on characteristics of the OUT design
基于特定设计样品的测试减少程序。
Ø Test reduction based on peak SAR level analysis
基于样品SAR值结果分析的测试减少程序。
Ø Test reduction based on simultaneous multi-band transmission considerations
基于样品多发射机同时工作时的测试减少程序。
Ü SAR measurements of terminals with multiple antennas and multiple transmitters.
具有多个天线和多个发射机的终端的SAR的测量。
Ü Deviation of dielectric characteristics of the tissue-equivalent liquids is relaxed up to 10 %.
组织液的介电特性的偏差放宽至10%。
Ü Uncertainty evaluation guidelines for temperature and dielectric parameter deviations of tissue-equivalent liquids.
组织液的温度以及液体介电常数偏移的不确定评估指导。
Ü Addition of the following annexes:
Ø Annex K (informative) Measurement uncertainty of specific fast SAR methods and fast SAR examples
附录K (参考性) **扫描SAR测试不确定评估以及举例说明。
Ø Annex L (informative) SAR test reduction supporting information
附录L (参考性) SAR测试减少判定程序支持信息。
Ø Annex M (informative) Applying the head SAR test procedures
附录M (参考性) 应用头部SAR测试进程。
Ø Annex N (informative) Studies for potential hand effects on head SAR
附录N (参考性) 研究手对头部SAR潜在的影响。
Ø Annex O (informative) Quick start guide